Topic : Chips 'n Chips Author : Michael Ruge Version : chips_x.hyp (01/05/2001) Subject : Dokumentation/Hardware Nodes : 1505 Index Size : 35662 HCP-Version : 3 Compiled on : Atari @charset : atarist @lang : @default : @help : @options : -i -s +zz -t4 @width : 75 View Ref-File Manchmal meckert auch das Laufwerk eine Cartridge an, hier die Auf- lösung der Blink-Codes Number of LED Blinks Error Description GREEN RED/AMBER ============================================================== 0 1 Too many files created/wrong cartridge 0 2 Maintainance track read error 0 3 Maintainance track write error 0 4 Drive not ready 0 5 No spare maintainance sectors 0 6 Cartridge write protect 0 7 Self test FAT/FED sector full 1 1 EPROM failed checksum test 1 2 Microcontroller internal RAM failure 1 3 Scratchpad RAM failed 1 4 Self test seek error 1 5 Seek error 1 6 Read Error 1 7 Write Error (1 1,2,3 Replace Drive / Laufwerk austauschen) (1 5,6,7 Replace Cartridge / Cartridge austauschen) 2 1 Disk controller (SERDES) failed 2 2 SERDES Sequencer RAM test 1 failed 2 3 SERDES Sequencer RAM test 2 failed 2 4 R/W buffer RAM address register failed test 1 2 5 R/W buffer RAM address register failed test 2 2 6 R/W buffer RAM failed test 1 2 7 R/W buffer RAM failed test 2 (2 1,2,3,4,5,6,7 Replace Drive / Laufwerk austauschen) 3 1 R/W buffer RAM port 0 failed 3 2 Amber/Red/Green LEDs port failed 3 3 R/W buffer RAM port 2 failed 3 4 Self test write error (scan process) 3 5 Invalid self test number 4 1 Spindle motor failed nach start 4 2 Spindle motor failed nach spin up nach speed 4 3 Spindle motor spins too fast (4 1,2,3 Replace Drive / Laufwerk austauschen) 5 1 Power supply failure (voltage out of spec) (5 1 Überprüfe Versorgungsspannungen +5V, +12V) 5 2 Spindle motor speed abnormal <> 0.5% or no servos (5 2 Cartridge austauschen) weiterblättern Kapitel Die Fehlercodes der SyQuest SQ555, Seite 1