Topic       : Chips 'n Chips
Author      : Michael Ruge
Version     : chips_x.hyp (01/05/2001)
Subject     : Dokumentation/Hardware
Nodes       : 1505
Index Size  : 35662
HCP-Version : 3
Compiled on : Atari
@charset    : atarist
@lang       : 
@default    : 
@help       : 
@options    : -i -s +zz -t4
@width      : 75
View Ref-File

   Manchmal meckert auch das Laufwerk eine Cartridge an, hier die Auf-
   lösung der Blink-Codes

   Number of LED Blinks    Error Description
   GREEN   RED/AMBER
   ==============================================================
     0       1               Too many files created/wrong cartridge
     0       2               Maintainance track read error
     0       3               Maintainance track write error
     0       4               Drive not ready
     0       5               No spare maintainance sectors
     0       6               Cartridge write protect
     0       7               Self test FAT/FED sector full

     1       1               EPROM failed checksum test
     1       2               Microcontroller internal RAM failure
     1       3               Scratchpad RAM failed
     1       4               Self test seek error
     1       5               Seek error
     1       6               Read Error
     1       7               Write Error
    (1       1,2,3           Replace Drive / Laufwerk austauschen)
    (1       5,6,7           Replace Cartridge / Cartridge austauschen)


     2       1               Disk controller (SERDES) failed
     2       2               SERDES Sequencer RAM test 1 failed
     2       3               SERDES Sequencer RAM test 2 failed
     2       4               R/W buffer RAM address register failed
                             test 1
     2       5               R/W buffer RAM address register failed
                             test 2
     2       6               R/W buffer RAM failed test 1
     2       7               R/W buffer RAM failed test 2
    (2       1,2,3,4,5,6,7   Replace Drive / Laufwerk austauschen)


     3       1               R/W buffer RAM port 0 failed
     3       2               Amber/Red/Green LEDs port failed
     3       3               R/W buffer RAM port 2 failed
     3       4               Self test write error (scan process)
     3       5               Invalid self test number

     4       1               Spindle motor failed nach start
     4       2               Spindle motor failed nach spin up 
                             nach speed
     4       3               Spindle motor spins too fast
    (4       1,2,3           Replace Drive / Laufwerk austauschen)


     5       1               Power supply failure (voltage out of spec)
    (5       1               Überprüfe Versorgungsspannungen +5V, +12V)
 

     5       2               Spindle motor speed abnormal <> 0.5% or
                             no servos
    (5       2               Cartridge austauschen)




     weiterblättern
     Kapitel Die Fehlercodes der SyQuest SQ555, Seite 1