View Ref-FileVDI Function Calling ProcedureThe GEMVDI is accessed through a 68x00 TRAP #2 statement. Prior to the
TRAP, register d0 should contain the magic number 0x73 and register d1
should contain a pointer to VDI parameter block. An example binding is as
follows:
.text
_vdi:
move.l #_VDIpb,d1
move.l #$73,d0
trap #2
rts
The VDI parameter block is an array of 5 pointers which each point to
a specialized array of WORD values which contain input parameters and
function return values. Different versions of the VDI support different
size arrays. The following code contains the 'worst case' sizes for these
arrays. Many newer versions of the VDI support larger array sizes. You can
inquire what the maximum array size that VDI supports by examining the
work_out array after a v_opnvwk() or v_opnwk(). Larger array sizes allow
more points to be passed at a time for drawing functions and longer
strings to be passed for text functions. The definition of the VDIparameter block follows:
.data
_contrl: ds.w 12
_intin: ds.w 128
_ptsin: ds.w 256
_intout: ds.w 128
_ptsout: ds.w 256
_VDIpb: dc.l _contrl, _intin, _ptsin
dc.l _intout, _ptsout
.end
The contrl array contains the opcode and number of parameters being
passed the function as follows:
contrl[x] Contents
0 Function Opcode
1 Number of Input Vertices in ptsin
2 Number of Output Vertices in ptsout
3 Number of Parameters in intin
4 Number of Output Values in intout
5 Function Sub-Opcode
6 Workstation Handle
7-11 Function Specific
contrl[0], contrl[1], contrl[3], contrl[5] (when necessary), and
contrl[6] must be filled in by the application. contrl[2] and contrl[4]
are filled in by the VDI on exit. contrl[7-11] are rarely used, however
some functions do rely on them for function-specific parameters.
For specific information on bindings, see the VDI Function Reference.